The aerial bundled cables designed for overhead distribution lines have all conductors made of aluminum 1350 and are insulated with XLPE. Phase and neutral cores are laid up in a bundle with a left hand lay. Cables are rated at 0.6/1 (1.2) kV and conform to AS/ NZS 3560.
-
Primarily used as overhead cable or air cable for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor. Polyethylene insulated conductors for temperatures...
-
Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can provided pre-pulled into...
-
IEC 60502 Al/PE Insulated Aerial bundled Cable is used as service line of supplying 600/1000 volt electricity in aerial way. Temporary service of power transmission line at construction sites. Service drop to connect electricity pole service entrance and applications. Second conductor or cable to...
-
Used for primary and secondary overhead distribution where limited space is available or desired for rights-of-way. Covered Line Wire also called Tree Wire - Used for spans where trees crowd the right-of-way, such as in wooded residential areas, when a minimum of interference with the environment...
-
Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts.As an option, this cable can provided pre-pulled into...
-
Used to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less. Operation temperatures should not to exceed 75°C for polyethylene insulated...
-
Use in aerial bundled conductor (ABC) systems for city power grid transmission line. Operating voltage up to 600/1000 volts. Main for overhead single-phase and three-phase electricity distribution and other purposes. Stable working temperature -10°C to 80°C
-
Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Voltage rating is 600 volts. As an option, this cable can provided pre-pulled into...
-
Used to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. May be used as pole line secondary with service splices at the pole or mid-span. Works at 600 volts (0.6kV) or less (phase to phase) at a...
-
Aluminum 600V URD cable is designed for use in secondary distribution circuits, where installed in duct or direct burial applications. Maximum operating temperature is not to exceed 90°C in wet and dry locations. Works at 600 volts (0.6kV) or less. As an option, this cable can provided pre-...